Industrial Horizontal Compressors—Troubleshooting Guide

Excessive Vibration

Possible Causes

 

What To Do      


Inadequate compressor support

Strengthen or replace baseplate, grout baseplate

Improper foundation or mounting Tighten mounting or rebuild foundation

Valves broken, stuck or leaking Inspect, clean or repair valves

Loose sheave or belt Tighten or adjust sheave

Worn wrist pin or wrist pin bushing Replace

Worn connecting rod bearingReplace

Loose valve, piston, or packing Tighten or replace as necessary

Unbalanced load Inspect valves or consult factory

Bad motor bearing Lubricate according to motor manufacturers instructions

Foreign material in cylinder Inspect and clean cylinder area
 

 

 

Corken, Inc.
A Unit of IDEX Corporation
3805 N.W. 36th Street, Oklahoma City, OK 73112 U.S.A.
(405) 946-5576  
FAX   (405) 948-7343