Horizontal LPG Compressors—Troubleshooting Guide

Interstage Pressure Is Too Low

Possible Causes

 

What To Do      


First stage valves broken, stuck or leaking

Inspect, clean or repair valves

First stage piston rings worn Inspect, clean or repair valves

Variation of inlet or discharge pressure conditions Review and confirm conditions

 

 